# Blueprint Error: "The Model Manager is currently unavailable. Please try again shortly".

### **Problem**:

When I select Devices from the Assets section or when I attempt to close a period I receive one of the following errors: "The Model Manager is currently unavailable. Please try again shortly" "The period end settings could not be read" The Blueprint Administrator log file shows a an message code of "**MessageCode: 141254**"

How can I correct this problem?

---

### **Resolution**:

The symptoms are caused by a malformed 'C:\Program

Files\PharosBlueprint\SettingsCache\ServerSettings.xml' cache. To fix the problem please see the steps below for the version of Blueprint Enterprise you have installed.

### **For Blueprint 3.5**

1. Stop the TaskMaster service.
2. Delete the file 'C:\Program Files\PharosBlueprint\SettingsCache\ServerSettings.xml' (it will be automatically re-created correctly).
3. Start the TaskMaster service.

### **Blueprint 4.2 through 5.2**

1. Stop the service "Pharos Systems TaskMaster".
2. Open the directory "C:\ProgramData\PharosSystems\Blueprint\SettingsCache" and create a new folder called "old".
3. Copy the two files named below in the directory in step 2 to the Old directory you created above.

***ServerLastKnownGood.xml***

***ServerSettings.xml***
4. Delete these two files.
5. Start the service "Pharos Systems TaskMaster".

*The files will be re-created once the service is started.

## Related

- [Blueprint Administrator Error (141254): "The Model Manager is currently unavailable. Please try again shortly."](/blueprint-administrator-error-141254-the-model-manager-is-currently-unavailable-please-try-again-shortly.md)
- [Package creation error: "Communication Error - please try again: Server Closed Connection."](/package-creation-error-communication-error-please-try-again-server-closed-connection.md)
- [Popup Error: Failed to listen for incoming Popup jobs. You will not be able to use Popup printing for the duration of this session. Please report this incident to a system administrator.](/popup-error-failed-to-listen-for-incoming-popup-jobs-you-will-not-be-able-to-use-popup-printing-for-the-duration-of-this-session-please-report-this-incident-to-a-system-administrator.md)
- [Error when trying to re-manage a Konica Minolta device with Pharos software after device was reset to factory defaults.](/error-when-trying-to-re-manage-a-konica-minolta-device-with-pharos-software-after-device-was-reset-to-factory-defaults.md)
- [Failed to initiate Logon DLL because 'Could not open com port!' Could not initialize card reader. Please contact the administrator"](/failed-to-initiate-logon-dll-because-could-not-open-com-port-could-not-initialize-card-reader-please-contact-the-administrator.md)