When I update configuration settings at the Analyst, they do not appear at Collectors
  • 02 Apr 2024
  • 1 Minute to read
  • Dark
    Light
  • PDF

When I update configuration settings at the Analyst, they do not appear at Collectors

  • Dark
    Light
  • PDF

Article summary

When I update configuration settings at the Analyst, the changes are not actioned at Collectors.


Data and configuration settings are cached at Collectors in order to reduce load on the Analyst and provide extra redundancy. New configuration settings will not be requested until the existing data expires.

You can clear the cached data manually, so that Collectors will request new data and settings the next time it needs them. To clear cached data on a Collector server, open Blueprint Administrator on the server and go to the Replication Management screen in the Replication section. Click the Update button to clear cached data and force the Collector to update its settings the next time it needs them.