MENU
    Blueprint: An Error "Cannot contact the Blueprint Analyst" is received after installing Pharos Blueprint Administrator on a client workstation
    • 23 Apr 2024
    • 1 Minute to read
    • Dark
    • PDF

    Blueprint: An Error "Cannot contact the Blueprint Analyst" is received after installing Pharos Blueprint Administrator on a client workstation

    • Dark
    • PDF

    Article summary

    Blueprint: An Error "Cannot contact the Blueprint Analyst" is received after installing Pharos Blueprint Administrator on a client workstation


    Environment

    • Pharos Blueprint Analyst v5.0

    • Pharos Blueprint Administrator v5.0

    Symptoms

    • ERROR: "Cannot contact the Blueprint Analyst or the services are not running."


    Cause

     The WCF (Windows Communication Foundation) security settings were different between the client and server.

    Resolution

    The correct this problem, the WCF security settings between the client and the server must match.

    1. On the Blueprint server, go to \Program Files (x86)\PharosSystems\Blueprint\Bin (NOTE: on a 32-bit server, this would be in \Program Files\PharosSystems\Blueprint\Bin) and copy these files:

      global.serviceModel.behaviors.config
      global.serviceModel.bindings.config
      global.serviceModel.client.config
      global.serviceModel.extensions.config
      global.serviceModel.services.config

    2. Paste them into the \Program Files\PharosSystems\Blueprint\bin directory on the client workstation, overwriting the duplicates.

      There is no need to restart any services or processes on the client.


    Was this article helpful?


    Changing your password will log you out immediately. Use the new password to log back in.
    First name must have atleast 2 characters. Numbers and special characters are not allowed.
    Last name must have atleast 1 characters. Numbers and special characters are not allowed.
    Enter a valid email
    Enter a valid password
    Your profile has been successfully updated.