- 23 Apr 2024
- 1 Minute to read
- Print
- DarkLight
- PDF
Blueprint: An Error "Cannot contact the Blueprint Analyst" is received after installing Pharos Blueprint Administrator on a client workstation
- Updated on 23 Apr 2024
- 1 Minute to read
- Print
- DarkLight
- PDF
Blueprint: An Error "Cannot contact the Blueprint Analyst" is received after installing Pharos Blueprint Administrator on a client workstation
Environment
Pharos Blueprint Analyst v5.0
Pharos Blueprint Administrator v5.0
Symptoms
ERROR: "Cannot contact the Blueprint Analyst or the services are not running."
Cause
The WCF (Windows Communication Foundation) security settings were different between the client and server.
Resolution
The correct this problem, the WCF security settings between the client and the server must match.
On the Blueprint server, go to \Program Files (x86)\PharosSystems\Blueprint\Bin (NOTE: on a 32-bit server, this would be in \Program Files\PharosSystems\Blueprint\Bin) and copy these files:
global.serviceModel.behaviors.config
global.serviceModel.bindings.config
global.serviceModel.client.config
global.serviceModel.extensions.config
global.serviceModel.services.configPaste them into the \Program Files\PharosSystems\Blueprint\bin directory on the client workstation, overwriting the duplicates.
There is no need to restart any services or processes on the client.