- 04 Apr 2024
- 1 Minute to read
- Print
- DarkLight
- PDF
Does the Omega support external devices that connect using RS232
- Updated on 04 Apr 2024
- 1 Minute to read
- Print
- DarkLight
- PDF
The SmartPAD contains an internal serial port, which can be used to attach a serial card reader. This port is accessed by removing the back of the SmartPAD.
Note: If the customer removes the back of the SmartPAD, it voids the Pharos warranty to the customer. However, Pharos staff are allowed to take the SmartPAD back off to connect a card reader.
The port is a 9-pin RS-232 serial male connector that supports card readers configured to 9600 baud, 8, n, 1 that send an ID string terminated by a non printable char like CR. The DTR pin on the socket can supply 5 Volts at 500 mA to the card reader. The pin-outs for the port are as follows:
Pin Name
1 NC
2 Rx
3 Tx
4 DTR
5 GND
6 NC
7 RTS
8 CTS
9 NC
NC = not connected