Problem:
I am unable to re-manage a Konica Minolta device using the Pharos software after the device has had been reset to factory defaults. The below error message can be seen in the Pharos KM iMFP Management Service log file.
10/6/2016 12:00 Error Pharos.ManagementConsole.Setup.SetupHandler Setup ip.add.ress.removed An error occurred when trying to set up authentication on the device. DeviceViewModel.<Install>b__a => DeviceViewModel.InstallHelper => SetupHandler.Setup
10/6/2016 12:00 Error Pharos.KonicaMinoltaCommon.LogUtils LogSetupErrorDetails ip.add.ress.removed ****Setup Error information**** DeviceViewModel.InstallHelper => SetupHandler.Setup => LogUtils.LogSetupErrorDetails
10/6/2016 12:00 Error Pharos.KonicaMinoltaCommon.LogUtils LogSetupErrorDetails ip.add.ress.removed Process Name: AppReqExtSetApplicationDetails DeviceViewModel.InstallHelper => SetupHandler.Setup => LogUtils.LogSetupErrorDetails
10/6/2016 12:00 Error Pharos.KonicaMinoltaCommon.LogUtils LogSetupErrorDetails ip.add.ress.removed Error Code: 21 DeviceViewModel.InstallHelper => SetupHandler.Setup => LogUtils.LogSetupErrorDetails
10/6/2016 12:00 Error Pharos.KonicaMinoltaCommon.LogUtils LogSetupErrorDetails ip.add.ress.removed
Error Description: There is no HDD DeviceViewModel.InstallHelper => SetupHandler.Setup => LogUtils.LogSetupErrorDetails
10/6/2016 12:02 Debug Pharos.ManagementConsole.Setup.SetupManagerController CreateSetupManager ip.add.ress.removed
Resolution:
Performing a factory reset on a device will disable the HDD. This has to be re-enabled again andis done by a Konica Minolta Technician.
Note: Pharos Support does not have instructions on how to do this on the various models of devices.